Contact

Emerson Rosemount 2051TG / 2051TA Coplanar Pressure Transmitter | Technical Guide, Model Codes and Price Advantage

...
Emerson Rosemount 2051TG / 2051TA Coplanar Pressure Transmitter | Technical Guide, Model Codes and Price Advantage
Emerson Rosemount 2051TG / 2051TA Coplanar Pressure Transmitter | Technical Guide, Model Codes and Price Advantage

⚙️ Emerson Rosemount 2051TG / 2051TA Coplanar Pressure Transmitter \| Technical Guide, Model Codes and Price Advantage

🎯 Strategic Importance

Rosemount 2051TG and 2051TA are compact intelligent pressure transmitters using Emerson's Coplanar™ platform.

  • 2051TG → Gauge (relative) pressure measurement

  • 2051TA → Absolute pressure measurement

Thanks to the coplanar design, the transmitter can be easily integrated directly into manifolds and process connections.

Key advantages: ✔ Compact body design ✔ High measurement accuracy ✔ Long-term stability ✔ Low maintenance cost ✔ HART®, FOUNDATION™ Fieldbus and PROFIBUS PA support ✔ Cost advantage in EPC and OEM projects

Compared to the 3051 series, its more economical structure makes it widely used especially in OEM machines, skid systems and standard process applications.

 

🔎 Meaning of Model Codes

Parameter Description
TG Gauge Pressure Transmitter
TA Absolute Pressure Transmitter
Measurement Range Low, medium and high pressure ranges
Process Connection NPT, ANSI, DIN Flange
Output 4–20 mA HART®, FOUNDATION™ Fieldbus, PROFIBUS PA
Housing Aluminum or Stainless Steel
Wetted Parts 316L SS, Hastelloy, Monel, Tantalum
Certifications ATEX, IECEx, FM, CSA, SIL options
 
 
 
 
 

Note: Communication protocols and certification options vary depending on the ordered model.

 

📊 Product Code Examples

  • 2051TG1A02A1AB4 → Gauge Pressure → ½" NPT → 316L SS → 4–20 mA HART® → IP66

  • 2051TA2A22A1AB4 → Absolute Pressure → 2" DIN Flange → 316L SS → 4–20 mA HART® → NEMA 4X / IP66

  • 2051TG3A05F1AB4 → Gauge Pressure → FOUNDATION™ Fieldbus → ANSI Flange → Stainless process connection

  • 2051TA4A2B21P1AB4 → Absolute Pressure → Hastelloy C → PROFIBUS PA → Stainless Housing

📑 Product codes must always be verified against Emerson datasheet and selected according to process conditions.

 

⚙️ Operating Principle

  • Sensor diaphragm detects process pressure.

  • Electronic sensor cell converts this pressure into a digital signal.

  • Microprocessor applies temperature compensation.

  • Output signal:

    • 4–20 mA

    • HART®

    • FOUNDATION™ Fieldbus

    • PROFIBUS PA

Transmitted to PLC or DCS systems.

 

📊 Technical Specifications

Parameter Feature
Measurement Type Gauge / Absolute Pressure
Output 4–20 mA
Communication HART®, FOUNDATION™ Fieldbus, PROFIBUS PA
Process Connections ANSI, DIN, NPT
Wetted Parts 316L SS, Hastelloy
Housing Aluminum / Stainless Steel
Protection IP66 / NEMA 4X
Certifications ATEX, IECEx, FM, CSA, SIL options
 
 
 
 
 
 

🏭 Industrial Applications

  • Power Plants • Steam lines • Turbine auxiliary systems • Vacuum systems

  • 🛢️ Petrochemical and Refineries • Gas pressure • Process lines • Tank pressure

  • 🧪 Chemical Industry • Reactor pressure • Corrosive processes • Chemical storage

  • 💧 Water and Wastewater • Line pressure • Pump outlets • Filtration systems

  • 🔧 OEM and Skid Systems • Compact process equipment • Package systems • Machine manufacturers

 

⚡ Operational Advantages

✔ Compact coplanar design ✔ Easy manifold integration ✔ High long-term stability ✔ Low Total Cost of Ownership (TCO) ✔ Global certification compliance ✔ Fast RFQ and global sourcing support

 

🔧 Commissioning

  • Zero Trim

  • Sensor Trim

  • Loop Test

  • HART® communication verification

  • Process connection check

  • Pressure sealing test

  • Output verification

 

⚠️ Troubleshooting

Problem Possible Cause Solution
Measurement drift Calibration Zero Trim
Unstable signal Vibration Check process connection
Communication error HART® setting Verify configuration
No output Power supply issue Check power source
 
 
 
 
 
 

🔄 Comparison: 2051TG vs 2051TA

Feature 2051TG 2051TA
Measurement Type Gauge Pressure Absolute Pressure
Reference Atmosphere Vacuum
Usage Line Pressure Vacuum and Gas Systems
OEM Usage Very Common Common
 
 
 
 
 
 

❓ Frequently Asked Questions

What is the main difference between 2051TG and 2051TA? 2051TG measures relative pressure referenced to atmosphere. 2051TA measures absolute pressure using internal vacuum reference.

Which communication protocols are supported? Standard: 4–20 mA HART®. Optional: FOUNDATION™ Fieldbus and PROFIBUS PA.

How long is the RFQ process? Yeşil Grup Enerji typically responds within 24–48 hours through its global sourcing network.

 

🌍 Global Supply and Technical Support

Yeşil Grup Enerji provides:

  • Model validation

  • Datasheet review

  • Technical configuration support

  • Cross-reference analysis

  • Global sourcing

  • Fast RFQ management

  • International project support

 

📞 Quotation and Technical Support

📧 [email protected] 📞 +90 505 696 61 00 🌐 www.yesilgrupenerji.com

 

✅ Conclusion

Emerson Rosemount 2051TG and 2051TA Coplanar Pressure Transmitter models; with compact Coplanar™ design, high accuracy measurement performance and industrial communication protocols, provide reliable pressure measurement in energy, petrochemical, chemical, water & wastewater and OEM processes. Suitable for both gauge and absolute pressure applications, they stand out with wide configuration options, long service life and low Total Cost of Ownership.

Yeşil Grup Enerji supports projects with model validation, technical configuration, datasheet verification, alternative product analysis, global sourcing and fast RFQ management, helping determine the most suitable technical and commercial solution. Through its international supply network, it offers competitive quotations, flexible delivery options and reliable engineering support.

Contact Form