The Endress+Hauser Cerabar series comprises pressure transmitters designed to measure the pressure of gases and liquids in process industries. The product family includes compact pressure instruments, transmitters for process applications, hygienic designs and solutions incorporating diaphragm seals.
Selecting a Cerabar transmitter requires more than comparing pressure ranges. The measurement type, sensor technology, process temperature, process connection, wetted materials, output signal, communication options and required approvals must be evaluated together.
This guide introduces the main Cerabar product families and explains the key technical criteria for selecting a suitable model. For model-specific specifications, the relevant manufacturer product page and Technical Information document should be used as the primary references.
|
Model / family |
Main distinction |
Key selection considerations |
|
PMP11 / PMP21 / PMP23 |
Compact pressure transmitters; specifications vary by model and configuration |
Measuring range, sensor, process connection and output |
|
PMC11 / PMC21 |
Compact models with oil-free ceramic measuring cells |
Suitability of the ceramic sensor for the application and required pressure range |
|
PMC51 / PMP51 |
Cerabar M family with different measuring-cell technologies |
Sensor type, process conditions and required measurement performance |
|
PMP55 |
Cerabar M model used with diaphragm seal solutions |
Fluid compatibility, diaphragm seal design and temperature effects |
|
PMP71B / PMC71B |
Cerabar B-generation instruments; technical specifications must be evaluated individually |
Measuring cell, communication, accuracy and safety requirements |
|
PMP43 |
Pressure transmitter for hygienic applications within the Compact Line |
Hygienic process connection, temperature limits and required approvals |
|
PMP75 |
Pressure transmitter with a fully welded metal diaphragm seal |
High-temperature applications, diaphragm seal configuration and process materials |
Technical note: The models listed in this table should not be assumed to share the same measuring ranges, accuracy specifications, communication options or certifications. Even variants within the same product family may differ depending on their order codes.
Compact Cerabar models can be considered for standard industrial pressure measurement when their measuring range and process connection are suitable for the application. Within this group, the model code, measuring cell and output options should be assessed together.
These models are designed for compact pressure measurement applications. However, PMP11, PMP21 and PMP23 should not be assumed to have identical technical specifications. Their measuring ranges, pressure references, electrical connections, process connections and output options should be checked against the relevant Technical Information document.
PMC11 and PMC21 are compact models featuring oil-free capacitive ceramic sensors. However, the measurement type and technical limits must be evaluated separately for each model.
The manufacturer lists the following key specifications for the Cerabar PMC21:
Pressure measuring range: 100 mbar to 40 bar
Reference accuracy: ±0.3%
Process temperature: −25 °C to +100 °C
Measurement type: Absolute or gauge pressure
Sensor: Oil-free capacitive ceramic measuring cell
These are general specifications published for the PMC21. Before ordering, the current technical documentation for the selected version should be checked against the actual process conditions.
For PMC11, numerical specifications such as measuring range and accuracy should likewise be verified against the current Technical Information document for the relevant product.
When selecting between compact models, comparing only the price or maximum pressure rating is insufficient. Sensor technology, process conditions, connection compatibility and the electrical requirements of the control system should also be considered.
When evaluating Cerabar M models, the differences in sensor technology and process connection are important selection factors.
PMC51: Model family featuring a ceramic measuring cell.
PMP51: Model family associated with silicon sensor technology.
PMP55: Model family used with diaphragm seal solutions.
These distinctions do not mean that every configuration within a model family has the same measuring range, accuracy or temperature limits. In particular, diaphragm seal systems may be affected by the seal geometry, diaphragm material, fill fluid, process connection and temperature conditions.
When selecting a Cerabar M instrument, establish the following requirements:
Whether absolute or gauge pressure must be measured
Normal operating pressure and maximum process pressure
Minimum and maximum process temperatures
Chemical properties of the process fluid
Process connection and wetted materials
Output signal and compatibility with the control system
Whether a diaphragm seal is required
Source verification: Technical specifications for this model group should be verified against the manufacturer's Technical Information document corresponding to the actual order code. A general product-family description is not a substitute for the specifications or performance requirements of a particular variant.
PMP71B and PMC71B are models within the Cerabar B generation. However, their sensor designs, measuring ranges, accuracy, temperature limits and communication options should not be treated as interchangeable.
Technical evaluation should focus on the following:
Required pressure measurement type and measuring range
Sensor and measuring-cell configuration
Reference accuracy and the overall measurement effects under actual operating conditions
Process connection and wetted materials
Output and communication options
Project-specific requirements, such as hazardous-area approvals or functional safety
Communication options such as HART, PROFIBUS PA or PROFINET over Ethernet-APL should only be specified when supported by the relevant model and order configuration. Their availability across the entire Cerabar range, or across every variant, should not be assumed.
Similarly, approvals such as SIL, ATEX or IECEx cannot be confirmed solely from the product family name. Compliance must be verified against the documentation for the specific instrument and the applicable certificate scope.
Rather than listing every technical variant of PMP71B and PMC71B in this general guide, this section summarizes the principal selection criteria. Exact values should be taken from the current manufacturer documentation for the selected product.
Cerabar PMP43 is a pressure transmitter for hygienic applications within the Endress+Hauser Compact Line. It can be considered for food and beverage processes and other applications requiring an appropriate hygienic design. Suitability should be determined according to the required process connection, cleaning conditions and applicable approvals.
The manufacturer's product page lists the following key specifications:
|
Technical specification |
Information published on the manufacturer's product page |
|
Pressure measuring range |
400 mbar to 100 bar |
|
Reference accuracy |
Standard: 0.1%; Platinum: 0.075% |
|
Process diaphragm |
316L |
|
Process temperature |
Depending on configuration, ranges including −40 °C to +130 °C or −20 °C to +200 °C are listed |
These are general product-page specifications. The applicable limits and features must be confirmed for the selected order code.
Different PMP43 technical documents cover communication options such as 4–20 mA analog, 4–20 mA HART and IO-Link. This does not mean that all communication options are available simultaneously on the same instrument. The appropriate option must be selected according to the order configuration.
For hygienic applications, process connection, surface and material requirements, cleaning conditions and required approvals should be evaluated separately. Approvals such as 3-A or EHEDG should only be claimed when supported by the documentation for the relevant product configuration.
Manufacturer source: Cerabar PMP43 – product information, technical documentation and approvals
Cerabar PMP75 is a digital pressure transmitter with a fully welded metal diaphragm seal for measuring the pressure of gases or liquids. It can be considered for applications where direct contact between the process fluid and the measuring cell is unsuitable, or where process conditions require a diaphragm seal.
The manufacturer's product page lists the following key technical specifications:
|
Technical specification |
Information published on the manufacturer's product page |
|
Pressure measuring range |
400 mbar to 400 bar |
|
Accuracy |
0.075% + diaphragm seal effect |
|
Process temperature |
Depending on configuration, options from −70 °C to +400 °C |
|
Listed wetted-material options |
316L, Alloy C276, Monel, tantalum and PTFE foil options |
These values do not indicate that every material and temperature option is available across all measuring ranges. The suitable configuration must be determined using the manufacturer's technical documentation.
The following factors are important when selecting a diaphragm seal:
Chemical properties of the process fluid and material compatibility
Minimum and maximum process temperatures
Normal operating pressure and potential pressure surges
Diaphragm seal type, diaphragm material and connection geometry
Suitability of the fill fluid for the process conditions
Installation position and temperature-related measurement effects
The diaphragm seal is part of the measurement system. Therefore, considering only the transmitter's nominal accuracy is insufficient; the additional measurement effects introduced by the diaphragm seal must also be evaluated.
Manufacturer source: Cerabar PMP75 – product information and technical documentation
The following criteria should be evaluated together when selecting a suitable Cerabar model.
First, establish whether the application requires gauge or absolute pressure measurement. These measurement types use different reference pressures, so the selection should not be based on the pressure range alone.
Determine the normal operating pressure, minimum and maximum values, and potential overpressure conditions. The instrument's measuring range must suit the application while meeting the required measurement performance.
The choice between ceramic and silicon sensor technologies should be evaluated in the context of the model design and process conditions. Sensor type alone does not determine overall instrument performance; the measuring range and other technical limits must also be checked.
Process temperature is different from ambient temperature. Wetted materials must be chemically compatible with the process fluid. For diaphragm seal applications, temperature effects and the properties of the fill fluid must also be included in the selection assessment.
Threaded, flanged or hygienic connection options should be selected according to the mechanical requirements of the application. Installation space, vibration, pressure surges and compatibility with the existing process connection should also be checked.
The suitability of options such as 4–20 mA, HART or IO-Link must be verified against the instrument's order configuration and the control system requirements. A communication option available for one model family should not automatically be assumed to be available for other models.
Requirements such as ATEX, IECEx, SIL or hygienic approvals should be defined according to the project specification. Compliance must be confirmed using the documentation for the exact instrument variant and the applicable certificates.
When replacing a Cerabar instrument, a similar model name or overlapping measuring range is not sufficient to establish compatibility. The technical suitability of the replacement for the existing system must be verified.
Use the following checklist:
Full model and order code of the existing instrument
Measurement type and pressure range
Sensor and measuring-cell characteristics
Process connection and wetted materials
Process and ambient temperature limits
Power supply, output signal and communication
Required certifications and safety approvals
Installation dimensions, electrical connections and accessories
Production status of the existing product and technical documentation for the proposed alternative
Important: A new model should not be described as a direct equivalent until a technical comparison has been completed. Replacement decisions should be based on the actual order codes and the requirements of the application.
PMP and PMC codes help distinguish different Cerabar models and measuring-cell options. For example, PMC11 and PMC21 use oil-free ceramic sensors. However, it is not accurate to assign a single sensor technology to every PMP or PMC model. The relevant product documentation should be consulted.
The Cerabar range includes models supporting both measurement types. However, the available measurement type depends on the selected model and configuration. The required pressure reference should be confirmed before ordering.
PMP43 is a pressure transmitter for hygienic applications within the Compact Line. Suitability should be assessed by checking the process connection, temperature limits, material requirements and required approvals.
PMP75 can be evaluated for processes requiring a diaphragm seal, within the pressure and temperature limits specified by the manufacturer. Diaphragm material, fill fluid and measurement effects should be included in the selection process.
These communication options are available on certain models and configurations. It should not be assumed that every Cerabar instrument supports the same protocols. The full model and order code must be checked.
Yes, but direct equivalence should not be assumed. Measuring range, sensor, process connection, materials, communication, installation and certifications must be compared to establish technical suitability.
Yeşil Grup Enerji is not an official distributor or authorized representative of Endress+Hauser. As an independent, brand-neutral industrial supplier, Yeşil Grup Enerji provides support for Cerabar products in the following areas:
Model and order-code verification
Technical documentation and configuration review
Product evaluation against process requirements
Cross-reference and replacement assessment for older models
Global sourcing and RFQ management
Project-specific quotations and technical comparison
When requesting a quotation, providing the full model code of the existing instrument, required pressure range, process connection, operating temperature, communication requirements and any mandatory certifications helps facilitate an accurate product assessment. Final technical suitability should be confirmed against the manufacturer's documentation and the project specification.
Email: [email protected]
Website: https://www.yesilgrupenerji.com/